UPERSERVER 6015B-3/6015B-T User's Manual
Rebuilding Arrays
Note 1: Rebuilding applies to Fault Tolerant array (RAID 1) only.
If an array Build process is interrupted or when one critical member is missing,
you must perform a Rebuild to restore its functionality. For a critical array rebuild
operation, the optimal drive is the source drive.
Note 2: If no spare array exists and a hard disk drive fails, you need to create a
spare before you can rebuild an array.
To Rebuild an array:
1. From the Main Menu, select Manage Arrays (as shown in the screen below).
From the List of Arrays, select the array you want to Rebuild.
2. Press <Ctrl> and <R> to Rebuild.